Description: I. LS162 Transmission Meter Introduction LS162 transmission meter is a compact and small transmission meter that can simultaneously test three parameters of light transmittance, ultraviolet rejection rate and infrared rejection rate. It is suitable for the display, exhibition, production, quality inspection, inspection and other occasions. The window film transmission meter can test the material optical properties such as automotive explosion-proof films, architectural films and laminated glass. The instrument has been widely used in solar film manufacturers, automotive film distribution, automotive film retail sales system. LS162 transmission meter display II. LS162 Transmission Meter Application LS162 solar film tester test different materials III. LS162 Transmission Meter Parameters UV peak wavelength 365nm IR peak wavelength 940nm Visible light 380nm-760nm full wavelength, in line with CIE photopic luminosity function Resolution 0.1% Measurement accuracy better than ± 2% (colorless and uniform transparent material) Maximum sample thickness <8mm Weight About 165 g (batteries excluded) Dimension 120mm × 25mm × 75mm Power supply 4 AAA alkaline dry batteries LS162 solar film transmission meter appearance IV. LS162 Transmission Meter Characteristics 1. The window film transmission meter has simple operation and the measurement is fast. Just put the measured object into the test slot then the visible light transmittance, ultraviolet and infrared rejection rate will be immediately displayed on the interface. LS162 window tint meter test stick-film glass 2. The instrument has small size and it is very convenient to carry out; the test card slot is 8mm wide, which can directly test the car windshield. LS162 transmission meter test car side windshield 3. The instrument has a data lock function. After the test is completed, press the HOLD button to lock the test data. The data will remain on the display interface after taking away the tested material. 4. LS162 portable solar film transmission meter has real-time dynamic calibration function. When there is no test object, the instrument will automatically return to the original data state to ensure more accurate test data. LS162 window tint meter original status 5. The transmission meter is powered by 4 AAA alkaline dry batteries with ultra-low power consumption. And the instrument will automatically shut down after 3 minutes without any operation. With this design, the instrument is more energy efficient. V. LS162A Transmission Meter Qualification Transmission meter patent certificate VI. LS162 Transmission Meter Operation Video VII. LS162 Transmission Meter Packaging Details No. Description Quantity Unit 1 LS162 Transmission Meter 1 pcs 2 AAA battery 4 pcs 3 User Manual 1 pcs 4 Certificate/warranty card 1 pcs 5 Packing box dimension 18*11*5 cm(L*W*H) 1 pcs LS162 transmission meter package VIII. LS162 Transmission Meter After-Sales Service The meter has one-year warranty. If the instrument works abnormally, please send the whole instrument to our company for maintenance Provide users with spare parts and lifelong maintenance services Provide the users with the meter inspection service Free technical support for long term IX. FAQ about LS162 Transmission Meter 1. The difference between LS162 (940nm) and LS162A (1400nm) window film transmission meters The main difference between LS162 and LS162A is that the IR bands are different. The infrared peak wavelength of LS162 is 940nm and the LS162A is 1400nm. These two bands are more representative bands. The absorbing film has a better infrared rejection effect at 940nm.The metallic film (Insulation by reflection) has a better infrared rejection effect at 1400nm. Please choose the appropriate instrument according to your own film. 2. The difference between LS162 and LS163 window film transmission meters LS162 measuring notch width is 8mm, LS163 measuring notch width is 6mm; LS162 use point light source, while LS163 use parallel light path. The latter has higher data accuracy when measuring thick materials; LS162 can only measure visible light transmittance, infrared and ultraviolet rejection rate, while LS163 can measure infrared and ultraviolet transmittance in addition to these three data; LS163 has three display interfaces, the screen can be rotated in four directions and has a screen backlight, but LS162 does not. 3. The difference between LS162 and LS101 window film transmission meters LS162 use point light source, while LS101 use parallel light path. The latter has higher data accuracy for measuring thick materials; LS162 can only be powered by battery, while LS101 can also be powered by USB cable in addition to battery; LS101 has screen backlight, while LS162 has no screen backlight; Except for the above differences and the differences in appearance, the other parameters of LS101 and LS162 are completely the same.
Price: 85.68 USD
Location: guangdong
End Time: 2025-01-03T14:16:07.000Z
Shipping Cost: 11.21 USD
Product Images
Item Specifics
All returns accepted: ReturnsNotAccepted
Origin: Mainland China
Size: 120mm *75mm *25mm(L*W*H)
Focal Length: 1
MPN: LS162
Model Number: LS162
Weight: 165g
Hign-concerned Chemical: None
Certification: CE
Brand Name: linshang
Brand: linshang
Class: Split Beam Spectrometers
Wavelength Range: UV: 365,VL: 380-760nm,IR: 940nm
Measurement Range: 0-100%
Available Variations
Color: CHINA
Price: 85.68 USD
Available Quantity: 10
Quantity Sold: 0