Description: From the manufacturer: Backlit analog/digital display Interchangeable probe adapter module Error-free visual indication Auto-ranging Multiple probe use Available in SI units INTRODUCTION The Victoreen Model 190 is compatible with Geiger-Mueller (GM) detectors, neutron probes, proportional counters, and scintillation probes operating from 300 to 1300 volts. Depending on probe selection, the Model 190 detects alpha, beta, gamma, neutron, or X-ray radiation within an operating range of 1 μR/h to 1 R/h or 1 CPM to 1,000,000 CPM. The unit is available with either an MHV or a BNC connector to provide the user with versatility in probe selection. Visual indication of selected parameters, as well as measured values, are displayed on the analog/digital display. APPLICATION The Model 190 Survey and Count Rate Meter is an easy-to-use instrument designed to meet the high technology requirements of Health Physics, Medical Physics, and Non-Destructive Testing applications. FEATURES LCD Display Readout • 2.6 inches (6.6 cm) x 2.0 inches (5.1) cm • Analog scale has fifty-one elements arranged in a radius arc. Each element represents 2% of full scale. Scale markings are 0, 2, 4, 6, 8, and 10. Scale length is 2.2 inches (5.6 cm) • Scale multiplier is 0.0001 to 1 million, depending on the probe selected and the units activated • 16-character alphanumeric display shows digitized average of the bar graph value. Displays operational units such as radiation unit changes, response time changes, data, and labels Pushbutton Controls • Light: Activates a background light for a preset or indefinite amount of time • Mode: Rolls through and displays the available units for the selected mode of operation • Log: Enters and sequentially labels the displayed data into a data log • Rate/Integ: Allows the user to select the mode of display • Resp Time: Rolls through and displays available response times (3, 6, 12, and 24 seconds) for user selection • Audio: Allows the user to turn on/off the audio indicator SPECIFICATIONS Operating Ranges (dependent on selected probe) Toggles and selects rate units: μR/hr mR/hr R/hr CPM CPS μSv/hr mSv/hr DPM Bq/cm2 μCi/cm2 and the complementary units in the integrate mode: μR mR R CTS D μSv mSv Bq μCi with the integrated time value in seconds Accuracy Within 10% of reading between 10% to 100% of full scale indication on any range, exclusive of typical energy dependence. Accuracy is probe dependent Detector Accepts GM detectors, neutron probes, scintillation probes, and proportional counters operating at high voltages between 300 and 1300 volts Adapter Module Contains calibration data and high voltage settings for a specified probe. The module is available with an MHV connector. Specify the type of connector with order Part number 190060 for MHV adapter module By using multiple replaceable probe adaptor modules, each module can be assigned to a specific probe. The module's EPROM stores the calibration factors for a specific probe. When plugged into a Model 190 Survey and Count Rate Meter, it automatically sets the high voltage and activates the calibration data set for the specific probe. By using modules married to specific probes, the user has the convenience of using only one Model 190 with multiple probes for survey work Log Logs 211 data points and sequentially labels data points. (Data retrieval requires the Model 190-1A Infrared Communicator). With the communicator, alphanumerics up to 16 characters can be programmed into the Model 190 to name the locations of individual data points to be collected. The location name is displayed when the Log button is pressed. Press the Log button again, and the data point is stored Power Four 9-volt batteries, 200 hours operation, automatically indicates when battery is low Warm Up Time 15 second diagnostic check Check Source Environmental Temperature Range - 10°C to + 60°C Relative Humidity 0 to 95%, non-condensing Construction Molded ABS plastic, splash-proof case Probe fits into side-mounted ABS plastic probe holder with Velcro ® straps Dimensions 3.75 in (w) x 9.2 in (d) x 2.1 in (h) (9.2 x 23.4 x 5 cm) Weight (without probe) 1 lb 9 oz (708.7 g) CHP Consultants dba CHP Surplus est. 2002 chpconsultants.com We offer 30-day return policy on our inventory. If you are not satisfied with an item, please contact us so we can work out a solution to your satisfaction. Due to the variety of the items, we sell through our store, we are only able to thoroughly test our items labeled as “Radiation Detectors”. We are happy to answer further questions on any item if we can. Please do not hesitate to message us if more information is needed. We are easy to reach during regular business hours. Monday through Friday 9-3.We take pain staking efforts to pack all items quickly and properly for safe shipping.We can consolidate shipping. If you place more than one order and wish to consolidate, simply message us prior to shipping and we can reduce shipping costs. Local pick up is available Oak Ridge, TN. Internal Use Barcode: 18452685Location: 11C We stand behind our eBay store. Check out CHPSurplus here for various miscellaneous equipment at a low price.
Price: 350 USD
Location: Oak Ridge, Tennessee
End Time: 2024-08-23T18:55:20.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Victoreen
Type: Radiation Survey Meter
Model: 190
Country of Manufacture: United States
MPN: 190