Description: QIAGEN QIAcube DNA/RNA Purification System Specifications Used tested working QIAGEN QIAcube DNA/RNA Purification System. Sold "as is". Comes as pictured, nothing more, nothing less. Please Note the Missing Cover Panel Specifications Technical data Power: 100–240 V AC, 50/60 Hz, 650 VA Mains supply voltage fluctuations are not to exceed 10% of nominal supply voltages. Note: The apparent power can exceed 650 VA for up to 2 seconds during the centrifuge acceleration and can reach an approximate value of 1000 VA.; Fuse: 2x T6.3A L 250V; Overvoltage category: II Operating temperature 18 to 28ºC (64.4 to 82.4ºF) Relative humidity 15–75% (non-condensing) Place of operation For indoor use only Pollution level 2 Environmental class 3K2 (IEC 60721-3-3) Storage conditions Temperature: 15ºC to 3 0ºC (59ºF to 86ºF) in manufacturer’s package; Relative humidity: Max. 75% (non-condensing); Environmental class: 1K2 (IEC 60721-3-1) Instrument dimensions Dimensions (hood closed): width 65 cm (25.6 in.), height 58 cm (22.8 in.), depth 62 cm (24.4 in.); Dimensions (hood open): width 65 cm (25.6 in.), height 86 cm (34 in.), depth 62 cm (24.4 in.); Mass: QIAcube Connect: 71.5 kg (157.6 lb.), Accessories: 3 kg (6.6 lb.) Centrifuge 10,640 rpm maximum, 12,000 x g maximum, swing-out rotor maximum 45°, 12 rotor positions Shaker Speed 100–2000 rpm, amplitude 2 mm, heating range of ambient temperature to 70°C (158°F), ramp-up time of <5 minutes from ambient temperature to 55°C (±3°C). Difference in the temperature detected by the internal sensor and the temperature of the sample liquid is approximately –2°C. Pipetting system Syringe size 1 ml, pipetting range 5–900 µl Table capacity Up to 12 samples per run Data output USB stick: USB2.0; Compatible OS: Windows 8, Windows 7, Windows Vista, Windows XP (SP3 or later); Mac OS x 10,1 or later; Operating temperature range: 0ºC to 35ºC; Operating humidity range: 10 to 90% (with no condensation); Storage temperature range: –20ºC to 60ºC (–4ºF to 140ºF); Storage humidity range: 10 to 90% (with no condensation); Formatting: FAT32 UV lamp Wavelength: 278nm; Optical power: 200-300mW Software QIAGEN protocols are pre-installed on the QIAcube Connect. Altitude Up to 2000 m (6500 ft) Transportation conditions –25°C to 60°C (–13°F to 140°F) in manufacturer's package; Max. 75% relative humidity (non-condensing); Environmenal class: 2K2 (IEC 60721-3-2) Disclaimer: "The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item." © Copyright 2023 MedicaPros. All rights reserved.
Price: 1649.99 USD
Location: Columbus, Ohio
End Time: 2025-01-28T17:17:19.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 14 Days
Refund will be given as: Money Back
Return policy details:
Brand: QIAGEN
MPN: QIAcube
Model: QIAcube