Description: Qiagen QIACube Automated Nucleic Acid Purification & Extraction System 650 VA Condition: Used in Clean, Excellent working condition.qiagen Cat. No. / ID #: 9002864 DescriptionQIAcube Connect is designed to perform fully automated purification of nucleic acids and proteins in molecular biology applications. The system is intended for use by professional users trained in molecular biological techniques and the operation of QIAcube Connect.Automates over 80 QIAGEN kits with over 140 standard protocols for DNA, RNA and protein sample processingOptional protocol customization expands the use to over 3000 protocolsGet reproducible results with less hands-on timeMonitor runs remotely, for quick response times, through the QIAsphere App QIAcube Connect is highly suitable for academic research laboratories as well as pharmaceutical, biotechnology, and biomedical research laboratories performing applications, such as:Sequencing/sequencing analysisGene expression analysisGenotypingProteomicsMicrobiome researchHuman identification and forensics SpecificationsSerial #: 10012 Technical dataPower: 100–120 V AC, 50/60 Hz, 650 VA Mains supply voltage fluctuations are not to exceed 10% of nominal supply voltages. Note: The apparent power can exceed 650 VA for up to 2 seconds during the centrifuge acceleration and can reach an approximate value of 1000 VA.; Fuse: 2x T6.3A L 250V; Overvoltage category: IIOperating temperature18 to 28ºC (64.4 to 82.4ºF)Relative humidity15–75% (non-condensing)Place of operationFor indoor use onlyPollution level2Environmental class3K2 (IEC 60721-3-3)Storage conditionsTemperature: 15ºC to 30ºC (59ºF to 86ºF) in manufacturer’s package; Relative humidity: Max. 75% (non-condensing); Environmental class: 1K2 (IEC 60721-3-1)Instrument dimensionsDimensions (hood closed): width 65 cm (25.6 in.), height 58 cm (22.8 in.), depth 62 cm (24.4 in.); Dimensions (hood open): width 65 cm (25.6 in.), height 86 cm (34 in.), depth 62 cm (24.4 in.); Mass: QIAcube Connect: 71.5 kg (157.6 lb.), Accessories: 3 kg (6.6 lb.)Centrifuge10,640 rpm maximum, 12,000 x g maximum, swing-out rotor maximum 45°, 12 rotor positionsShakerSpeed 100–2000 rpm, amplitude 2 mm, heating range of ambient temperature to 70°C (158°F), ramp-up time of <5 minutes from ambient temperature to 55°C (±3°C). Difference in the temperature detected by the internal sensor and the temperature of the sample liquid is approximately –2°C.Pipetting systemSyringe size 1 ml, pipetting range 5–900 µlTable capacityUp to 12 samples per runTouchscreen10.4” TFT Touchscreen, active area 211.2 x 158.4 mm, resolution 800*600 SVGAData outputUSB stick: USB2.0; Compatible OS: Windows 8, Windows 7, Windows Vista, Windows XP (SP3 or later); Mac OS x 10,1 or later; Operating temperature range: 0ºC to 35ºC; Operating humidity range: 10 to 90% (with no condensation); Storage temperature range: –20ºC to 60ºC (–4ºF to 140ºF); Storage humidity range: 10 to 90% (with no condensation); Formatting: FAT32UV lampWavelength: 278nm; Optical power: 200-300mWSpecial featureHandheld scanner; Scan pattern: Area Image (838 x 640-pixel array); Motion tolerance: Up to 610 cm/s (240 in/s) for 13 mil UPC at optimal focus; Symbol contrast: 20% minimum reflectance difference; Decode capability: Reads standard 1D, PDF, 2D, Postal and OCR symbologySoftwareQIAGEN protocols are pre-installed on the QIAcube Connect.AltitudeUp to 2000 m (6500 ft)Transportation conditions–25°C to 60°C (–13°F to 140°F) in manufacturer's package; Max. 75% relative humidity (non-condensing); Environmenal class: 2K2 (IEC 60721-3-2)Sku: BJBD.I28.3013/
Price: 795 USD
Location: Huntington Beach, California
End Time: 2024-11-15T13:45:37.000Z
Shipping Cost: 345 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: QIAGEN
Expiration Date: n/a
Model: QIACube
MPN: QIACube
Country/Region of Manufacture: Switzerland
Intended Use/Discipline: Biological Laboratory, Medical Laboratory, Microbiological Laboratory
California Prop 65 Warning: n/a