Cane Creek

Fluke Biomedical ProSim 8 Vital Signs & ECG Patient Simulator 3979409

Description: The Following Items Are Included: Fluke Biomedical ProSim 8 Vital Signs Simulator (BC# 43431-L/T*) AC Adapter/Charger USB PC Interface Cable User Manual On CD-ROM Hard Carrying Case BE SURE TO CHECK OUR EBAY STORE FOR OTHER ITEMS! Fluke Biomedical ProSim 8 Vital Signs Simulator8-in-1 multifunction simulator tests ECG (including fetal ECG and arrhythmias), respiration, temperature, IBP, cardiac output, NIBP, SpO2, and Rainbow multi-wavelength waveformsProSim 8 patient simulator enables you to complete preventive maintenance testing with one device in less than five minutes, reducing average test time by up to 88%Includes Carrying Case & Accessories As Listed Above!     Working Condition: ExcellentCondition: RefurbishedWarranty: 1 YEAR WARRANTY   Fluke ProSim 8 Vital Signs Simulator The 8-in-1 ProSim 8 Vital Signs Simulator offers fast and comprehensive preventative maintenance (PM) testing for your entire patient monitor fleet. Designed to get you in and out of most PM locations in minutes, this multifunction simulator tests ECG (including fetal ECG and arrhythmias), respiration, temperature, IBP, cardiac output, NIBP, SpO2, and is capable of testing Rainbow multi-wavelength waveforms. Featuring specialized stay-connected ECG posts for secure lead connections, physiologically-synchronized pulses across all parameters, and customizable patient pre-sets and autosequences, the ProSim 8 patient simulator provides unbeatably fast and easy complete monitor testing. Barcode-scanner compatibility and wireless PC interface, direct printing, data transfer and reporting, along with advanced, integrated technologies and works-every-time performance allow top confidence in patient monitor fleet performance and supports passing regulatory audits with ease.   Key Features: All-in-one complete monitor testing 80 % smaller and 17 lbs/7.7 kilos lighter than predecessor technology 8-in-1 multifunction simulator tests ECG (including fetal ECG and arrhythmias), respiration, temperature, IBP, cardiac output, NIBP, SpO2, and Rainbow multi-wavelength waveforms Stay-connected ECG posts for easy/secure ECG snap and lead connections Custom SpO2 r-curve for accurate testing of the latest and future oximetry technologies Static pressure linearity testing Repeatable NIBP simulation (+/- 2 mmHg) for dynamic pressure repeatability testing Physiologically synchronized pulses across all parameters Barcode scanning and direct data capture and printing functionality Onboard, customizable patient pre-sets and autosequences for fast/easy testing Multi-language user interface offers choice of language selection Integrated, easily-replaceable long-life battery   Specifications: General Specifications Temperature Operating: 10 °C to 40 °C (50 °F to 104 °F) Storage: -20 °C to +60 °C (-4 °F to 140 °F) Humidity 10 % to 90 % non-condensing Altitude 3,000 meters (9,843 ft) Dimensions (L x W x H) 14.5 cm x 30.2 cm x 8.6 cm (5.7 in x 11.9 in x 3.4 in) Display LCD color display Communication USB device upstream port: Mini-B connector for control by a computer USB host controller port: Type A, 5 V output, 0.5 A max load. Connector for keyboard, barcode reader, and printer Wireless: IEEE 82.15.4 for control by a computer Power Lithium-ion rechargeable battery Battery charger 100 V to 240 V input, 15 V/2.0 A output. For best performance, the battery charger should be connected to a properly-grounded ac receptacle Battery life 9 hours (minimum), 100 NIBP cycles typical Weight 1.87 kg (4.2 lb) Safety standards EN/IEC 61010-1:2001 Certifications CE, CSA, C-TICK N10140 , RoHS Electromagnetic compatibility (EMC) IEC 61326-1:2006 Detailed Specifications Normal-sinus-rhythm waveform ECG reference The ECG amplitudes specified are for Lead II (calibration), from the baseline to the peak of the R wave. All other leads are proportional Normal sinus rhythm 12-lead configuration with independent outputs referenced to right leg (RL). Output to 10 universal ECG jacks, color-coded to AHA and IEC standards High-level output 0.5 V/mV ± 5 % of the ECG amplitude setting available on a BNC connector Amplitude 0.05 mV to 0.5 mV (0.05 mV steps); 0.5 mV to 5.0 mV (0.25 mV steps) Other leads are proportional to Lead II (reference lead) in percentage per: Lead I: 70 Lead II: 100 Lead III: 30 Lead V1: 24 Lead V2: 48 Lead V3: 100 Lead V4: 120 Lead V5: 112 Lead V6: 80 Amplitude accuracy ± (2 % of setting + 0.05 mV) ECG rate 10 BPM to 360 BPM in 1 BPM steps Rate accuracy ± 1 % of setting ECG waveform selection Adult (80 ms) or pediatric (40 ms) QRS duration ST-segment elevation Adult mode only. -0.8 mV to +0.8 mV (0.1 mV steps). Additional steps: + 0.05 mV and - 0.05 mV Power-on default 60 BPM, 1.0 mV, adult QRS and ST-segment elevation of 0 mV Pacemaker waveform Pacer pulse Amplitude: 0 (off), ± 2, ± 4, ± 6, ± 8, ± 10, ± 12, ± 14, ± 16, ± 18, ± 20, ± 50, ± 100, ± 200, ± 500, and ± 700 mV for lead II (reference lead) Accuracy: Reference lead II: ± (5 % setting + 0.2 mV) All other leads: ± (10 % setting + 0.4 mV) Pacer pulse width 0.1 ms, 0.2 ms, 0.5 ms, 1 ms, and 2 ms ± 5 % Paced arrhythmias Atrial 80 BPM Asynchronous 75 BPM Demand with frequent sinus beats Demand with occasional sinus beats Atrio-ventricular sequential Noncapture (one time) Nonfunction Power-on default Amplitude 5 mV, width 1 ms, atrial waveform Arrhythmia Baseline NSR 80 BPM PVC focus Left focus, standard timing (except where specified) Supraventricular arrhythmia Atrial fibrillation (coarse or fine); atrial flutter; sinus arrhythmia; missed beat (one time); atrial tachycardia; paroxysmal atrial tachcardia; nodal rhythm; and supraventricular tachycardia Premature arrhythmia Premature atrial contraction (PAC); premature nodal contraction (PNC); PVC1 left ventricular; PVC1 left ventricular, early; PVC1 left ventricular, R on T; PVC2 right ventricular; PVC2 right ventricular, early; PVC2 right ventricular, R on T; and multifocal PVCs Ventricular arrhythmia PVCs 6, 12, or 24 per minute; frequent multifocal PVCs; bigeminy; trigeminy; multiple PVCs (one-time run of 2, 5, or 11 PVCs); monoventricular tachycardia (120 to 300 BPM in 5 BPM steps); poly-ventricular tachycardia (5 types); ventricular fibrillation (coarse or fine); and asystole Conduction defect First-, second-, or third-degree heart block; and right- or left-bundlebranch block Advanced cardiac life support Shockable pulseless arrest rhythms: Ventricular fibrillation (coarse), ventricular fibrillation (fine), unstable polymorphic ventricular tachycardia Non-shockable pulseless arrest rhythms: Asystole Symptomatic bradycardia: Sinus bradycardia (< 60 BPM) 2nd degree AV block, mobitz type I 2nd degree AV block, mobitz type II Complete/3rd degree AV block Right bundle branch block Left bundle branch block Symptomatic tachycardia: regular narrow-complex tachycardia (QRS < 0.12 seconds): Sinus tachycardia > 150 BPM Supraventricular Tachycardia Symptomatic tachycardia: regular wide-complex tachycardias (QRS ≥ 0.12 seconds): Sinus tachycardia > 150 BPM Supraventricular tachycardia SVT with aberrancy Irregular tachycardia: Atrial fibrillation (coarse and fine), atrial flutter, unstable monomorphic ventricular tachycardia (120 BPM to 300 BPM), torsade de pointes/polymorphic ventricular tachycardia (long QT interval) ECG Performance testing Amplitude 0.05 mV to 0.5 mV (0.05 mV steps); 0.5 mV to 5.0 mV (0.25 mV steps) Other leads are proportional to Lead II (reference lead) in percentage per: Lead I: 70 Lead II: 100 Lead III: 30 Lead V1 through V6: 100 Pulse wave 30 BPM, 60 BPM, with 60 ms pulse width Square wave 0.125 Hz, 2 Hz, 2.5 Hz Triangle wave 0.125 Hz, 2 Hz, 2.5 Hz Sine wave 0.05 Hz, 0.5 Hz, 1, 2 Hz, 5 Hz, 10 Hz, 25 Hz, 30 Hz, 40 Hz, 50 Hz, 60 Hz, 100 Hz, and 150 Hz R-wave detection Waveform: Triangular pulse Rate: 30 BPM, 60 BPM, 80 BPM, 120 BPM, 200 BPM, and 250 BPM Width: 8 ms to 20 ms in 2 ms steps, and 20 ms to 200 ms in 10 ms steps Width accuracy: ± (1 % of setting + 1 ms) QRS detection Widths 8 ms to 20 ms in 2 ms steps, and 20 ms to 200 ms in 10 ms steps Width accuracy ± (1 % of setting + 1 ms) Rate 30 BPM, 60 BPM, 80 BPM, 120 BPM, 200 BPM, and 250 BPM R-Wave up slope 0.875 amplitude, 0.4375 x width R-Wave down slope Full amplitude, 0.5 x width S-Wave up slope 0.125 amplitude, 0.0625 x width Tall T-wave rejection Waveform QT Interval 350 ms T-Wave width 180 ms T-Wave shape ½ sinewave Amplitude 0 % to 150 % reference lead amplitude in 10 % steps Rate 80 BPM Rate accuracy ± 1 % of setting Amplitute accuracy ± (2 % of setting + 0.05 mV) ECG artifact Type 50 Hz, 60 Hz, muscular, baseline wander, respiration Size 25 %, 50 %, 100 % of the normal sinus R-Wave for each lead Lead select All, RA, LL, LA, V1, V2, V3, V4, V5, V6 Fetal/Maternal ECG Fetal heart rate (fixed) 60 BPM to 240 BPM in 1 BPM steps Fetal heart rate (IUP) 140 BPM at beginning, then varies with pressure Intrauterine-pressure waveforms Early deceleration, late deceleration, and acceleration Wave duration 90 seconds, bell-shaped pressure curve, from 0 mmHg to 90 mmHg and returning to 0 IUP period 2 min, 3 min, or 5 minutes; and manual Default settings FHR 140 BPM, early deceleration wave, manual Invasive blood pressure Channels 2, each independently settable with identical parameters and are individually electrically isolated from all other signals Input/output impedance 300 Ω ± 10 % Exciter input range 2 to 16 V peak Exciter-input frequency range DC to 5000 Hz Transducer sensitivity 5 (default) or 40 µV/V/mmHg Pressure accuracy ± (1 % of setting + 1 mmHg) accuracy guaranteed for dc excitation only Static pressure - 10 to + 300 mmHg in 1 mmHg steps Pressure units mmHg or Kpa Dynamic waveforms Types (default pressures): Arterial (120/80) Radial artery (120/80) Left ventricle (120/00) Right ventricle (25/00) Pulmonary artery (25/10) Pulmonary-artery wedge (10/2) Right atrium (central venous or CVP) (15/10) Pressure variability: Systolic and diastolic pressures are independently variable in 1 mmHg steps Swan-Ganz sequence Right atrium, right ventrical (RV), pulmonary artery (PA), pulmonary artery wedge (PAW) Cardiac catheterization Chambers: Aortic, pulmonary valve, and mitral valve Respiration artifact Arterial, radial artery, and left ventricle: 5 % to 10 % multiplication Other: 5 mmHg or 10 mmHg BP output Circular DIN 5-Pin Power-on default 0 mmHg Respiration Rate 0 (OFF), 10 BrPM to 150 BrPM in 1 BrPM steps Waves Normal or ventilated Ratio (inspiration:expiration) Normal 1:1, 1:2, 1:3, 1:4, 1:5 Ventilated 1:1 Impedance variations (Δ Ω) 0.00 Ω to 1.00 Ω in 0.05 Ω steps and 1 Ω to 5 Ω in 0.25 Ω steps Accuracy delta ± (5 % of setting + 0.1 Ω) Baseline 500 Ω, 1000 Ω (default), 1500 Ω, 2000 Ω, Leads I, II, III Accuracy baseline ± 5 % Respiration lead LA or LL (default) Apnea selection 12 sec, 22 sec, or 32 seconds (one-time events), or continuous (Apnea ON = respiration OFF) Power-on default 20 BrPM, delta 1.0 Ω Temperature Temperature 3.0 °C to 42.0 °C in 0.5 °C steps Accuracy ± 0.4 °C Compatibility Yellow Springs, Inc. (YSI) Series 400 and 700 Output Circular DIN 4-Pin Cardiac output Catheter type Baxter Edwards, 93a-131-7f Calibration coeffecient 0.542 (0 °C injectate), 0.595 (24 °C injectate) Blood temperature 36 °C (98.6 °F) to 38 °C (100.4 °F) ± 0.2 °C in 1 °C steps Injectate volume 10 cc Injectate temperature 0 °C or 24 °C Cardiac output 2.5, 5, 10 liters per minute ± 7.5 % Faulty-injectate curve Waveform for simulation available Left-to-right-shunt curve Waveform for simulation available Calibrated pulse 1.5 ° for 1 second Connector Circular DIN 7 pin Power-on default 5 liters per minute, 0 °C injectate, 37 °C blood temperature Non-invasive blood pressure Pressure units   Manometer (Pressure meter)   Pressure source   NIBP simulations Pulse 2 mmHg max into 500 ml NIBP system Volume of air moved 1.25 ml max Simulations (systolic/diastolic [MAP]) Adult: 60/30 (40), 80/50 (60); 100/65 (77); 120/80 (93); 150/100 (117); and 200/150 (167) and 255/195 (215) Neonatal: 35/15 (22); 60/30 (40); 80/50 (60); 100/65 (77); 120/80 (93) and 150/100 Pressure variability: systolic and diastolic pressures are variable by 1 mmHg Repeatability Within ± 2 mmHg (at maximum pulse size independent of device under test) Synchronization: normal Sinus heart rates: 30 BPM to 240 BPM Maximum rate at 1 ml: 240 BPM achievable with pulses up to 1 ml Maximum rate at 1.25 ml: 180 BPM Synchronization: arrhythmias Premature atrial contraction (PAC), premature ventricular contraction (PVC), atrial fibrillation, and missed beat Leak test Target pressure 20 mmHg to 400 mmHg Elapse time 0:30 min to 5:00 minutes: seconds in 30 second steps Leakage rate 0 mmHg/minute to 200 mmHg/ minute Pressure relief test range 100 to 400 mmHg * This item has been cleaned and handled in accordance with the manufacturer's instructions** The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item. For full Fluke ProSim 8 Vital Signs Simulator product specifications, please click here: ProSim 8 Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our Ebay Test Equipment Store. All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to contact us for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet. Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment. Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more! We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don't have a listing for a particular item that you are looking for. Please contact us as it may be fresh inventory waiting to be listed or we'll be glad to find it for you at the best price possible and put up an eBay listing for you! We Ship World Wide! We will attempt to ship your item(s) within 24 hours after payment has been received. To get a real-time shipping quote to your destination, enter your country and zip / postal code information into the shipping calculator and click "Get Rate".Many countries impose their own customs, duties, tariffs, taxes, etc. on items being shipped from a foreign country. We do not cover those cost's and we recommend that you contact your countries customs agency for that information.We Offer Multiple Quantity Price & Shipping Discounts, Email Us If You Are Interested In Larger Quantities. We accept credit card payment transactions via the online checkout system! The checkout process is designed so that it communicates with the merchant to confirm that payment has been made and cleared. Other methods of payment are outlined through the online checkout process. Winning bidders must contact us within 3 days after auction close if special payment arrangements are needed. Your payment is expected within 5 days after the auction close. Unpaid auctions will be forfeited after 5 days of the auction close and the Item(s) will be relisted for sale. Items will be shipped within 24 hours (1 Business Day) upon receipt of payment from the winning bidder. (Certain orders may take longer for processing due to comprehensive final service inspections) A Shipment Tracking number(s) will be provided to inform Buyers of their expected ETA (Estimated Time of Arrival). Tracking number(s) will be provided the same day as order shipment. Thank you ALL MAJOR CREDIT CARDS & PayPal ACCEPTED Sell Smarter with Kyozou.Inventory and Ecommerce Management

Price: 14949 USD

Location: Southgate, Michigan

End Time: 2024-09-19T20:12:04.000Z

Shipping Cost: N/A USD

Product Images

Fluke Biomedical ProSim 8 Vital Signs & ECG Patient Simulator 3979409Fluke Biomedical ProSim 8 Vital Signs & ECG Patient Simulator 3979409Fluke Biomedical ProSim 8 Vital Signs & ECG Patient Simulator 3979409Fluke Biomedical ProSim 8 Vital Signs & ECG Patient Simulator 3979409Fluke Biomedical ProSim 8 Vital Signs & ECG Patient Simulator 3979409Fluke Biomedical ProSim 8 Vital Signs & ECG Patient Simulator 3979409Fluke Biomedical ProSim 8 Vital Signs & ECG Patient Simulator 3979409Fluke Biomedical ProSim 8 Vital Signs & ECG Patient Simulator 3979409Fluke Biomedical ProSim 8 Vital Signs & ECG Patient Simulator 3979409Fluke Biomedical ProSim 8 Vital Signs & ECG Patient Simulator 3979409Fluke Biomedical ProSim 8 Vital Signs & ECG Patient Simulator 3979409Fluke Biomedical ProSim 8 Vital Signs & ECG Patient Simulator 3979409Fluke Biomedical ProSim 8 Vital Signs & ECG Patient Simulator 3979409

Item Specifics

Restocking Fee: No

Return shipping will be paid by: Buyer

All returns accepted: Returns Accepted

Item must be returned within: 30 Days

Refund will be given as: Money back or replacement (buyer's choice)

Brand: Fluke

MPN: Does Not Apply

Intended Use/Discipline: 8-in-1 multifunction simulator tester

Model: ProSim 8

Recommended

Fluke 376 FC True-RMS AC/DC Clamp Meter
Fluke 376 FC True-RMS AC/DC Clamp Meter

$375.00

View Details
Fluke 1AC-C2II VoltAlert Non-Contact Voltage Detector Pen Tester W/sound
Fluke 1AC-C2II VoltAlert Non-Contact Voltage Detector Pen Tester W/sound

$21.79

View Details
Fluke T5-1000 1000 Volt Continuity Current Electrical Tester - Working
Fluke T5-1000 1000 Volt Continuity Current Electrical Tester - Working

$79.99

View Details
New For Fluke TL75 Hard Point Test Lead Set Meter Probes -US
New For Fluke TL75 Hard Point Test Lead Set Meter Probes -US

$16.14

View Details
Fluke 381 Remote Display True-RMS AC/DC Clamp Meter with iFlex
Fluke 381 Remote Display True-RMS AC/DC Clamp Meter with iFlex

$299.95

View Details
Fluke 83V 83-V 83-5 87V 87-V 87-5 88V 88-V 88-5 Yellow Rubber Holster Cover Case
Fluke 83V 83-V 83-5 87V 87-V 87-5 88V 88-V 88-5 Yellow Rubber Holster Cover Case

$37.95

View Details
Fluke 1587 Digital FC Insulation Multimeter - 1000V
Fluke 1587 Digital FC Insulation Multimeter - 1000V

$450.00

View Details
Fluke 1AC-C2 II 200V-1000V Electrical Test Pen VoltAlert Non Contact Voltage
Fluke 1AC-C2 II 200V-1000V Electrical Test Pen VoltAlert Non Contact Voltage

$18.99

View Details
FLUKE 2AC-C2 VoltAlert Non-Contact Voltage Pen AC200-1000v Detector Tester Meter
FLUKE 2AC-C2 VoltAlert Non-Contact Voltage Pen AC200-1000v Detector Tester Meter

$24.80

View Details
Fluke 1587 + AC/DC CLAMP i410 USED FAST SHIPPING
Fluke 1587 + AC/DC CLAMP i410 USED FAST SHIPPING

$350.00

View Details