Description: Description Current Voltage Signal Generator 0-5V-10V 0-4-20mA Analog Constant Current Source Debugging KW_VCG002 Description: KW_VCG002 is a small current voltage signal generator that can generate 0-20mA current signal and 0-10V voltage signal. It has the functions of anti-reverse connection of input voltage, data saving by power failure (no operation for 6 seconds, parameters will be automatically saved), current output indicator. It is easy to use the module. Data is input through the code switch and output signal is updated immediately. This module is cost-effective and can be used by various manufacturers, companies, universities, and research institutions. Specifications: - Module Power Supply: DC 18-30V - Current Output: 0.01-25.00mA - Current Accuracy: ±0.008mA - Output Maximum Load: 500Ω - Voltage Output: 0.000-10.000V - Voltage Accuracy: ±0.003V - Voltage Output Load Capacity: 30mA - Step Value: Current 0.01mA; Voltage: 0.005V - PCB Board Size: 83 x 58mm - Shell Size: 83 x 58 x 33mm - N.W.: 78.9g Voltage Output Adjustment: - Turn the voltage knob clockwise to increase the output voltage and counterclockwise to decrease the output voltage. Press the knob to select the digit to be adjusted. The digit selected at this time will flash. Voltage Output Calibration: - 1. Record the real output voltage of 0.5V and 10V separately. For example, the actual measured outputs are 0.46V and 9.85V, respectively. - 2. Adjust the displayed voltage to be 0.5V. Press the voltage knob for 5s or more to enter into the first calibration point. After entering, adjust the calibration data to be 0.46, then press the voltage knob for 5s to exit the first calibration point. - 3. Adjust displayed voltage to be 10V. Then press the voltage knob for 5s or more to enter into the second calibration point. After entering, adjust the calibration data to be 9.85, then press the voltage knob for 5s to exit the second calibration point. - 4. The voltage calibration process is finished. Current Output Adjustment: - Turn the current knob clockwise to increase the output current and counterclockwise to decrease the output current. Press the knob to select the digit to be adjusted. The digit selected at this time will flash. Current Output Calibration: - 1. Record the real output current of 0.5mA and 20mA separately. For example, the actual tested outputs are 0.502mA and 24.77mA, respectively. - 2. Adjust the displayed current to be 0.5mA. Press the current knob for 5s or more to enter into the first calibration point. After entering, the calibration data is adjusted to 0.50 (the last digit can be rounded off). Then press the current knob for 5s to exit the first calibration point. If users cannot measure the output data of 0.5mA, the data of the first calibration point can be directly set to 0.50. - 3. Adjust the displayed current to be 20mA. Press the current knob for 5s or more to enter into the second calibration point. After entering, adjust the calibration data to be 24.77. Then press the current knob for 5s to exit the second calibration point. - 4. The current calibration process is finished. Payment Terms 1.We accept PayPal only. 2.All major credit cards are accepted through secure payment processor PayPal. 3.Payment must be received within 7 business days of auction closing. 4.We ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is correct before you pay. Shipping Terms - For remote regions, we will charge your extra shipping costs. Usually it cost about 35USD-50USD. We will contact you after your payment. Thanks for your understanding. Return Terms 1. If you receive defective item, please kindly notify us within 14 days. We will guide you the returning instruction for replacement or refund. 2. If you purchased in improper condition, please NOTE that the sipping and handling fee will not be refund, all return shipping fee should paid by the buyer unless item DOA. 3. We reserve the right to refuse any returns for objective reasons. Custom Duties & Taxes 1. Import duties, taxes, and charges are not included in the item price or postage cost. These charges are the buyer's responsibility. 2. Avoiding some unnecessary trouble, please check with your country's customs office to inform us what we should declare its value before shipping. Feedback 1. If you are dissatisfied for any reason, please don't be quick to leave us neutral or negative feedback. We work hard to make sure EVERY CUSTOMER 100% SATISFIED and resolve any problem for you and always leave positive feedback to all our customers. 2. If you are satisfied with the product you received, please kindly leave us a positive feedback and 5 star DSR. If there is any problem of your order, please feel free to contact us firstly, we are responsible and credible seller, will follow it for you asap. On Oct-31-20 at 00:27:14 PDT, seller added the following information:
Price: 29.15 USD
Location: Shenzhen
End Time: 2024-02-29T08:19:59.000Z
Shipping Cost: 4.99 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Return policy details:
MPN: Does Not Apply
Country/Region of Manufacture: China
Brand: Unbranded