Description: ECG600G Electrocardiograph Introduction ECG600G is an Electrocardiograph which can collect 12-lead ECG signal simultaneously and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, case database management. Function 1)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz. 2)Real-time and continuously record clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.). 3)Full-digital filter design, anti-baseline drift, AC and EMG interference. 4)Adjust the baseline automatically, optimize the print setting and optional rhythm leads. 5)In AUTO mode, finish recording by pressing the button once, which improves work efficiency. 6)Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal. 7)With the functions of auto-measurement, auto-analysis and auto-diagnosis for routine ECG parameters, which reduces the doctor’s burden and improves work efficiency. 8)Sync collection for 12-lead ECG, multiply printing formats, including 2×6+1(rhythm lead), 2×6, 3×4, 3×4+1(rhythm lead), 4×3, 4×3+1(rhythm lead), 6×2, 6×2+1(rhythm lead), rhythm 2, rhythm 3, rhythm 4, rhythm 5, rhythm 6, rhythm 7, channel record, etc. 9)Display of real-time 3/6/12-lead ECG, "Lead off" and "Lack of paper" on one screen, and with ECG DEMO mode. Auto-check and auto-analysis for ECG parameters, ECG waveform can be recorded manually or automatically. And patient information can be stored by case database. 10)Time print can be set to every 1/2/3/5/10/20/30/60 minutes. 11)Print setting, including “Print and save”(print waveform and save case), “Print no save”(only print waveform but not save case), “Save no print”(only save case but not print waveform). 12)AC/DC, built-in rechargeable lithium battery and auto-protection circuit, and automatic power off when there is no operation in appointed time. 13)Store more than 1000 cases, convenient for case review and statistic. 14)Multi-language(Chinese, English, French, Spanish, Turkish, Polish, Italian, German, Portuguese, Kazakh, Russian, Ukrainian, Vietnamese, Serbian, Slovenian and Slovak) interface and report. Performance Input mode: floating and defibrillation protection Input impedance: ≥2.5 MΩ Patient leakage current: <10 µA Frequency response: Rated input amplitude Input frequency and waveform Relative output response 1.0 0.67Hz~40Hz, Sine wave ±10%a 0.5 40Hz~100Hz, Sine wave +10 %, -30 %a 0.25 100Hz~150Hz, Sine wave +10 %, -30 %a 0.5 150 Hz ~ 500 Hz, Sine wave +10 %, -100 %a 1.5 ≤1Hz,200ms, Triangle wave +0 %, -10 %b a relative to 10Hz b relative to 200 ms Time constant:≥ 3.2s CMRR: >105dB Filter: power frequency(AC50/60 Hz), EMG(25 Hz/35 Hz (-3 dB)), baseline drift filter Recording way: thermal printing system Specification of recording paper: 110 mm(W)×20 m(L) high-speed thermal paper Time base selection(paper speed): 12.5 mm/s, 25 mm/s, 50 mm/s, error: ±5% Gain control(sensitivity): 5, 10, 20 mm/mV, accuracy is ±2%; Standard sensitivity: 10 mm/mV±0.2 mm/mV Recording mode: auto mode, rhythm mode and manual mode Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1) Safety classification: Class I, type CF defibrillation-proof applied part Polarization resistance voltage: ±610mV Noise level: ≤12 µVp-p ECG signal input sampling frequency: 32 kHz Waveform data processing sampling frequency: 1 kHz Sampling accuracy: 24-bit The minimum detection signal: 10 Hz, 20 µV(peak-peak value) deflected sinusoidal signal can be detected Pacing detection channel: standard II Accuracy of input signal: ±5% Amplitude quantization: ≤5µV/LSB Interchannel time deviation: <100 µs Power supply: AC: 100V~240V(50/60Hz) DC: 7.4V/3500mAh rechargeable lithium battery Degree of protection against ingress of liquid: IPX0 Working mode: continuous working Accessories Standard configuration: A lead cable A limb electrode A chest electrode A thermal recording paper A power cord An earth wire A user manual Physical characteristic Working environment Temperature: 5℃~40℃ Relative humidity: 25%~95%(non-condensing) Atmospheric pressure: 700 hPa~1060 hPa Transport and storage environment Temperature: -20 ℃~+55 ℃ Relative humidity: ≤95% Atmospheric pressure: 500 hPa~1060 hPa Dimension: 315mm(L)×215mm(W)×92mm(H) Weight: 1.7Kg
Price: 450 USD
Location: beijing
End Time: 2024-10-02T07:00:03.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
MPN: Does Not Apply
Operation: Digital
Intended Use/Discipline: Emergency Medicine, Array
Brand: CONTEC
Mounting: Handheld
Number of Leads: 12
Unit Type: Unit
Number of Channels: 6
Model: ECG600G
ECG & EKG Machine Type: Electrocardiograph
Features: Printer, Array
Country/Region of Manufacture: China
Unit Quantity: 1