Description: Up for auction is a brand new BaseLine® Chromatography Data System (CDS). This powerful yet affordable workstation meets all your chromatography data handling needs on a stand-alone data acquisition and analysis unit. The workstation is designed to improve daily workflow with easy-to-use graphical interfaces for data gathering, processing, interpretation, and reporting. It enables the user to acquire analog signals from up to two commercially available detectors with standard analogue output. The package includes the following items: 1. One stand-alone 2-channel data handling unit.2. One Chromatography Workstation (in English) on CD-ROM.3. One COM & USB cable.4. One set of signal cables.5. Two junction terminals.6. One copy of User Manual in English. Gross weight: 1 kg. Dimension: 30 x 24 x 6 cm. Please note the computer shown in the picture is not included in the package. BaseLine® CDS provides you with the best value data handling solution for upgrading your GC, flash chromatograph, biochromatograph, HPLC, and CE. Though priced at a fraction of an integrator, this PC-based chromatography data system offers the same power and performance as data systems that cost five to ten times more. l Replace paper records, integrators, and DOS-based systems. l No programming required – just plug and playl Export data for use with MS Word, Excel, Photoshop or CorelDraw SpecificationsNumber of channels: 2Input voltage: -5 mV-1.7 VInput impedance: > 10 MWDynamic range: 107Linearity: 0.1%Mininum resolution: 1 uVFrequency of sampling: 10 or 50/secManual integration enabledVarious methods for quantitative calculationEquipped with a remote starter to be connected to analytical instrument or Autosampler to receive the Start/Stop signals. They have been tested to work perfectly when replacing integrators on a variety of chromatography equipment. For example:Waters 441, 480, 481, 484, 486, 490E, 2487 UV-Visible Absorbance Detector, Waters 470, 472 Fluorescence Detector, Waters 430,431 Conductity Detector, Waters R401, R404, 410, 2410, 2414 Differiential Refractometer or Refractive Index Detector, Waters 460, 464 Electrochemical Detector.Shimadzu SPD-6A, SPD-6AV, SPD-10A, SPD-10AV UV-Visible Absorbance Detector, Shimadzu RF-535, RF-551, FLD-6 Fluorescence Detector, Shimadzu GC-9A FID Detector, GC-Mini2 FID Detector.ABI or Kratos or Spectroflow 757, 759A, 783, 783A, 785A UV-Visible Absorbance Detector, ABI 980 Fluorescence Detector.Spectra-Physics, Thermo Separation Products, LDC SpectroMonitor I, III, D, 3100, 3200, 5000, Spectra 100, SpectraSystem UV1000, UV2000, Spectra Focus Scanning Absorbance Detector.Hitachi or Merck 628, 655A, L-4000, L-4250, L-7400, L-7420, L-7450 UV-Vis Detector, F-1000, F-1200, F-1050, F-7485 Fluorescence Detector.HP 1050 LC.Hewlett Packard or HP 5890 Gas Chromatograph.Gow-Mac Instruments 580, 600 Gas Chromatograph.SRI instruments 8610 Gas Chromatograph.Varian 3410, 3400, 3600, CP-3800 Gas Chromatograph.LabAlliance or SSI Model 500, Model 506 UV Vis Detector.Linear 200, 201, 205, 206PHD UV-Visible Absorbance Detector, LC-304 Fluorescence Detector.Knauer Variable Wavelength Monitor, Refrative Index Detector.Bio-Rad 1801 UV Monitor, Bio-Rad 1640 Electrochemical Detector, Bio-Rad 1755 Refractive Index Detector.Perkin Elmer LC-95, 785A UV-Visible Absorbance Dector, LC-25 RI Detector.LKB, Pharmacia, GE Single Path Monitor UV-1, UV-M II, Uvicord SII, 2151 UV-Visible Absorbance Detector.AKTA prime, AKTA prime plus.Alltech 500, Varex II, Varex MKIII ELSD, Sedex 55, Sedex 75 ELSD, Polymer Laboratories EMD-950 Mass Detector, Evaporative Light Scattering Detector.Rainin Dynamax Absorbance UV-1, UV-C, UV-D Detectors.Acutech 500 UV/Vis Absorbance Detector HPLC. Varian PorStar MODEL 350 Refractive Index RI Detector.Varian ProStar 320 Absorbance Detector.Viscotek LR40 Laser Refractometer.Precision Instruments IOTA 2 Refracative Index Detector.HP 1047A Refractive Index RI RID Detector.HP 1037A RID Refractive Index Detector.Dionex AD20, AD25 Absorbance Detectors.Du Pont 860 Absorbance Detector.ESA 520 Absorbance Detector.Erma ERC-7512 Refractive Index RI Detector.Activon Linear 200 Absorbance Detector.And a lot more to be added later. Please check back! Can be used with NA 1500/1108 CARLO ERBA/FISONS/THERMO ORGANIC ELEMENTAL ANALYZER CHNS Computer RequirementsWindows 98, 2000, ME, XP, 7. The computer should have a minimum 64 MB RAM, both a serial and a USB port. Please note the system is compatible with 32-bit Windows operating systems but not 64-bit operating systems. This data system can be connected to a laptop PC Notebook equipped with a RS232 COM Port to PCMCIA Express Card Adapter. but not with a regular USB-COM adaptor.Please inquire if you have any questions.
Price: 299 CAD
Location: Scarborough
End Time: 2023-12-08T16:36:34.000Z
Shipping Cost: 20.2 CAD
Product Images
Item Specifics
Returns Accepted: ReturnsNotAccepted
Non-Domestic Product: No
Brand: BaseLine Chromtech
Unit Type: Unit
Custom Bundle: Yes
Chromatography Technique: High Performance Liquid Chromatography (HPLC)
MPN: Does Not Apply
Unit Quantity: 10
Modified Item: No