Cane Creek

ANDO AQ6140 1270 to 1650nm Multi Wavelength Optical Meter (Fully Tested)

Description: ANDO AQ6140 1270 to 1650nm Multi Wavelength Optical Meter Fully Tested Fully Functional: Tested With (Cert of Conformance) 14 Day ROR Additional Features:Ideal for Wavelength Analysis in D-WDM SystemsHighly accurate wavelength measurement: Realizes high accuracy measurement of ±0.003 nm. (at 1310 nm, 1550 nm)High resolvable separation: Minimum resolvable separation: 10 GHz or less (1550 nm: 80 pm)Capable of measurement for up to 256 channels: Wavelength and power measurement for up to 256 channelsSimple operation: Three-step (maximum) operation saves you from complicated operationEnlarge display of peak list: Can display enlarged data of one channel in the area normally displaying data of 5 channelsDrift measurement: Refers to measuring the time-passage changes wavelength and power. (up to 256 channels)Grid monitoring function: Useful function for checking wavelength shift of each gridComplete functions for monitoring WDM light source: Complete functions for stability analysis of light source such as 3D display of variable rate, time displacement display, variable rate trap function, etc.Complete memory functions: Can record measurement data and measurement conditions in floppy disk and internal memoryLarge-size (6.5-inch) color display: Can check waveform data and peak wavelength at a time by displaying waveforms and measurement data simultaneouslySpecifications:Applicable fiber: SMWavelength range: 1270 to 1650 nm (182 to 236 THz)Wavelength accuracy: ±2 ppm (1550 nm, 1310 nm: ±0.003 nm)Minimum resolvable separation: 10 GHz or less (1550 nm: 80 pm, equal power line input)Power accuracy: ±0.5 dB (1310/1550±30 nm, typ.)Level linearity: 1270 to 1600 nm: ±0.3 dB (input: -30 dBm or more)Polarization depending loss: 1270 to 1600 nm: ±0.5 dB; 1600 to 1650 nm: 1.0 dBMaximum number of line input: 256Minimum input level: 1270 to 1600 nm: -40 dBm (1 line input); 1600 to 1650 nm: -30 dBm (1 line input)Maximum input level: +10 dBm (total of all lines)Safe max. input level: +18 dBm (total of all lines)Return loss: 35 dB (PC)SN ratio: 35 dB (typ.) (noise band width: 0.1 nm, input: -25 dBm or more, spacing ≥ 100 GHz)Measurement time: ≤ 1.5 secDisplay: 6.5-inch color LCD (640 x 480 dots)Memory: Internal: Can memorize 10 measurement results and conditionsFloppy disk (3.5-inch 2HD): Can memorize measurement results and conditionsInternal hard disk drive: 9MB: can memorize measurement results and conditionsInterfaces: GP-IB: GP-IB (IEEE. 488.2); RS-232C: 9-pin D-subPrinter port: 25-pin D-sub (Centronics)VGA monitor: 15-pin D-subOptical connector: AQ9441 (FC) Universal AdapterPower requirements: AC 100 to 120/200 to 240 V, 50/60 Hz (47 to 63 Hz), 100 VAEnvironmental conditions: Operation temperature: 5 to 40 °C, storage temperature: -20 to +60 °C, humidity: 80 % RH or less (at 40 °C, no condensation)Dimensions: Approx. 425 (W) x 132.5 (H) x 450 (D) mmApplicationsCharacteristic evaluation of light source for WDMMeasures both wavelength and power up to 256 channels, and displays waveform and measurement result at a time. Capable of checking if it’s matched to advice of ITU-T and severe monitoring of grid. Also capable of displaying the list of peak wavelength and power.Long-term functionDisplays changes of peak wavelength and power of one channel. Below waveforms, displays not only current measurement result but also maximum rate, minimum rate or balance of maximum rate and minimum rate.Grid monitoring functionAnalyzes peak wavelength of set grid. Searches peak wavelength, or analyzes wavelength gap and changes of power within the grid.Standard screenThe waveform and the peaks are displayed simultaneously on the standard screen. It is used to monitor WDM system temperature characteristics and evaluate laser oscillators.3D display screenDisplays 3D waveforms and peak lists at a time. It helps to check the change of measurement result by time.List screenThis mode displays a list of the peak wavelengths, up to 14 at a time.Marker screenThe marker function simplifies tasks such as analysis of wavelength and power level difference.Label input screenLabel can be input up to 36 characters, so that file management can be easy.File screenMeasured waveform data can be saved in a variety of file formats. The file recall function makes it possible to make new measurement with the same measurement conditions as saved data, which is ideal for WDM system maintenance.Practical application in recent years of Wavelength Division Multiplexing (WDM) transmission technology for high-volume optical communication has led to the current situation in which we’re on the verge of producing 50 GHz-wavelength systems.Accordingly, demand for a higher-specification wavelength parameter tester is increasing. Such a tester can go a long way toward improving evaluation of transmission systems and optical devices.

Price: 5999.99 USD

Location: Livermore, California

End Time: 2024-03-08T08:15:00.000Z

Shipping Cost: N/A USD

Product Images

ANDO AQ6140 1270 to 1650nm Multi Wavelength Optical Meter (Fully Tested)ANDO AQ6140 1270 to 1650nm Multi Wavelength Optical Meter (Fully Tested)ANDO AQ6140 1270 to 1650nm Multi Wavelength Optical Meter (Fully Tested)ANDO AQ6140 1270 to 1650nm Multi Wavelength Optical Meter (Fully Tested)ANDO AQ6140 1270 to 1650nm Multi Wavelength Optical Meter (Fully Tested)ANDO AQ6140 1270 to 1650nm Multi Wavelength Optical Meter (Fully Tested)ANDO AQ6140 1270 to 1650nm Multi Wavelength Optical Meter (Fully Tested)ANDO AQ6140 1270 to 1650nm Multi Wavelength Optical Meter (Fully Tested)ANDO AQ6140 1270 to 1650nm Multi Wavelength Optical Meter (Fully Tested)ANDO AQ6140 1270 to 1650nm Multi Wavelength Optical Meter (Fully Tested)ANDO AQ6140 1270 to 1650nm Multi Wavelength Optical Meter (Fully Tested)

Item Specifics

All returns accepted: ReturnsNotAccepted

Model: AQ6140

Modified Item: No

Country/Region of Manufacture: Japan

Custom Bundle: No

MPN: AQ6140

Brand: ANDO

Recommended

VTG Japanese Ando Cloisonne Glass Enamel Round  Dish Tray in Mandela Pattern 7"
VTG Japanese Ando Cloisonne Glass Enamel Round Dish Tray in Mandela Pattern 7"

$37.49

View Details
Tadao Ando Architecture Of Silence Werner Blaser Naoshima Art Museum
Tadao Ando Architecture Of Silence Werner Blaser Naoshima Art Museum

$28.99

View Details
 Gorgeous Sweet Sayako Ando Beautiful  Japanese Idol Feminine Card
Gorgeous Sweet Sayako Ando Beautiful Japanese Idol Feminine Card

$8.00

View Details
Tadao Ando Yasushi Horibe Waro Kishi : Masterpieces and Lessons in Architecture
Tadao Ando Yasushi Horibe Waro Kishi : Masterpieces and Lessons in Architecture

$39.00

View Details
Tadao Ando - Architektur Der Stille / Architecture of Silence: Naoshima...
Tadao Ando - Architektur Der Stille / Architecture of Silence: Naoshima...

$18.14

View Details
Ando & Friends Andy Davis Design Australia Art Tee Shirt Size Small
Ando & Friends Andy Davis Design Australia Art Tee Shirt Size Small

$20.00

View Details
Tadao Ando: Process and Idea (English and Japanese Edition) By E
Tadao Ando: Process and Idea (English and Japanese Edition) By E

$32.60

View Details
ANDO AH5502B PDC PHS CELLULAR SIGNALLING TESTER
ANDO AH5502B PDC PHS CELLULAR SIGNALLING TESTER

$154.42

View Details
Bunraku The Puppet Theater by Tsuruo Ando 1970 First Edition HC DJ
Bunraku The Puppet Theater by Tsuruo Ando 1970 First Edition HC DJ

$20.00

View Details
Vintage Ando Silvered Cloisonne 4¾" Square Plate Yellow Flowers Design Handmade
Vintage Ando Silvered Cloisonne 4¾" Square Plate Yellow Flowers Design Handmade

$12.50

View Details